Run6
Touch_Panel AT mode VSWR METER Lo Power AT position Tank_length (m) Shunt inpedance Ez calc (MV/m) Ez design (MV/m) Power design value
Tank No. pulse deg FF FF_deg AT1 AT2 VAC1(S*A) VAC2(S*B) S**A(deg) S**B(deg) V1:Pf V2:Pf V3:Pf TK:T1 TK:T2 V1:Pr V2:Pr V3:Pr V1:VSWR V2:VSWR V3:VSWR AT1(bead) AT2(bead) S**A S**B Mohm/m S**A (T1>MV/m) S**B (T2>MV/m) S**A (Design>MV/m) S**B (Design>MV/m) S**A S**B
BUN1 4090 330.1 0 330.1 none none none 4 4 0 22 0 0.1 0.1 0 1.43 1.46 none 324.73
BUN2 3730 202.9 0 202.9 none none none 7 7 0 40 0 0.1 0.1 0 1.36 1.38 none 323.16
CHOP 4000 0.0 0 0.0 none none none 30 30 0 231 281 0.1 0 0 1.13 1.00 none 344.13
RFQ 4030 0.0 130 0.0 none none 2.04E-05 320 165 168 369 331 0 6 6 1.00 1.50 1.47
D01 3596 274.0 225 274.0 32.55 53.98 8.20E-06 1060 460 430 840 850 0 10 10 1.00 1.51 1.51 9.92 58.59 2.23 2.50 1059.66
D02 3919 234.0 225 234.0 28.53 34.01 1.21E-05 1180 460 530 1050 1030 0 0 0 1.00 1.14 1.13 41.00 34.00 9.44 64.29 2.67 2.70 1070.45
D03 3872 329.0 175 329.0 17.55 31.92 5.99E-06 950 400 400 910 910 0 0 0 1.00 1.23 1.20 34.00 32.00 7.32 64.01 2.82 2.90 962.06
S01 2872 25.9 100 25.9 61.42 59.09 5.86E-06 1.00E-05 -6deg +1deg 410 172 172 120 177 0 17 17 1.00 1.93 1.92 59.00 1.47 1.51 56.32 56.84 2.14 2.58 2.53 2.53 167.17 169.66
S02 2788 78.7 100 78.7 44.75 43.15 2.42E-06 3.42E-06 +3deg -3deg 480 211 204 210 200 0 22 21 1.00 1.98 1.96 44.00 45.00 1.54 1.58 56.71 56.58 2.78 2.68 2.73 2.73 202.76 208.12
S03 3781 115.7 120 115.7 61.09 51.31 2.21E-06 6.24E-07 -1deg -1deg 660 256 267 470 340 0 25 24 1.00 1.92 1.86 63.00 55.00 1.62 1.66 56.43 56.27 4.05 3.40 2.95 2.95 249.49 256.19
S04 3549 292.3 120 292.3 43.23 49.06 3.61E-06 2.52E-06 -4deg +5deg 780 332 319 450 300 0 15 11 1.00 1.55 1.46 52.00 60.00 1.70 1.74 56.09 55.90 3.86 3.11 3.19 3.19 307.69 316.07
S05 3611 259.7 80 259.7 39.50 40.54 2.68E-06 2.11E-06 +7deg 0deg 840 356 373 510 350 0 18 17 1.00 1.58 1.56 46.00 47.00 1.78 1.82 55.69 55.46 4.00 3.27 3.44 3.44 377.61 387.96
S06 3553 252.0 100 252.0 51.63 53.25 2.31E-06 2.82E-06 0deg +2deg 1130 480 510 530 570 0 20 20 1.00 1.64 1.55 60.00 61.00 1.86 1.90 55.23 54.97 3.97 4.06 3.74 3.74 471.24 484.29
S07 3625 215.2 130 215.2 54.89 73.37 1.39E-06 1.16E-06 -3deg +4deg 1110 480 470 530 480 0 20 20 1.00 1.61 1.64 59.00 77.00 1.95 1.99 54.72 54.46 3.86 3.63 3.74 3.74 497.24 509.99
S08 3374 350.0 120 350.0 68.79 62.17 9.20E-07 5.71E-07 +2deg -5deg 1140 470 500 500 550 0 20 20 1.00 1.55 1.62 73.00 67.00 2.03 2.06 54.21 53.95 3.66 3.79 3.74 3.74 522.60 535.06
S09 3452 296.9 90 296.9 58.98 62.48 7.90E-07 7.80E-07 +6deg -5deg 1220 470 500 530 510 0 20 20 1.00 1.52 1.54 63.00 66.00 2.10 2.14 53.69 53.44 3.68 3.57 3.74 3.74 547.37 559.49
S10 3351 182.8 80 182.8 51.37 53.64 9.80E-07 9.50E-07 +5deg 0deg 1140 510 540 590 580 0 10 20 1.00 1.42 1.49 59.00 60.00 2.17 2.21 53.19 52.95 3.80 3.73 3.74 3.74 571.47 583.27
S11 3436 260.9 100 260.9 43.56 44.95 8.70E-07 1.75E-06 0deg +2deg 1160 540 540 630 630 0 10 10 1.00 1.41 1.45 43.00 52.00 2.24 2.27 52.70 52.46 3.85 3.81 3.74 3.74 594.91 606.39
S12 3138 213.0 70 213.0 55.70 48.92 1.52E-06 9.80E-07 -8deg -9deg 1040 570 580 660 540 0 10 10 1.00 1.41 1.42 62.00 54.00 2.31 2.34 52.22 51.99 3.87 3.47 3.74 3.74 617.69 628.84
S13 3443 168.6 70 168.6 37.21 41.41 1.42E-06 1.49E-06 0deg -5deg 1330 580 580 630 640 0 10 10 1.00 1.43 1.41 43.00 47.00 2.37 2.40 51.76 51.53 3.71 3.71 3.74 3.74 639.82 650.63
S14 3302 97.1 80 97.1 47.31 52.75 1.01E-06 8.10E-07 -7deg -13deg 1310 600 600 630 670 0 10 10 1.00 1.43 1.30 53.00 59.00 2.43 2.45 51.31 51.10 3.65 3.74 3.74 3.74 661.29 671.78
S15 3353 192.9 70 192.9 41.44 49.73 1.77E-06 1.12E-06 +5deg +3deg 1270 630 610 690 620 0 20 10 1.00 1.44 1.35 47.00 55.00 2.48 2.51 50.88 50.67 3.76 3.54 3.74 3.74 682.10 692.28
DB1(S16B) 4000 8.0 0 8.0 51.55 none 8.60E-07 none +3deg 162 70 0 80 70 0 22 0 1.00 3.56 none 55.00 59.00 2.53 2.56 50.47 50.27 1.26 1.17 3.74 3.74 702.29 712.16
DB2(S16A) 4730 216.0 0 216.0 (67.08) none 1.61E-06 none +0deg 13 11 0 9 15 3.8 3.8 0 3.44 3.82 none